Personal Protective Equipment

Availability: In Stock

Infection prevention and control measures include, hand hygiene, personal protective equipment and waste management materials.

Description

Personal Protective Equipment

Infection prevention and control measures include, hand hygiene, personal protective equipment and waste management materials.


The Protective equipment consists of garments placed to protect the health care workers or any other persons to get infected.
These usually consist of standard precautions: gloves, mask, gown. If it is blood or airborne high infections, will include: Face protection, goggles and mask or face shield, gloves, gown or coverall, head cover, rubber boots.

Additional information

Weight 67 kg
Dimensions 131 × 11 × 160 cm

Reviews

There are no reviews yet.

Be the first to review “Personal Protective Equipment”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPersonal Protective Equipment removeAR–K8 4D Colour Doppler Ultrasound removeBlood Bank Refrigerator removeTonometer removeLed Operating Lamp YD02–5+5 removePeritoneal dialysis remove
NamePersonal Protective Equipment removeAR–K8 4D Colour Doppler Ultrasound removeBlood Bank Refrigerator removeTonometer removeLed Operating Lamp YD02–5+5 removePeritoneal dialysis remove
Image
SKUincredible-leatherintelligent-rubber-computer-39225733gorgeous-cotton-plate-05277582awesome-leather-coat-50022656incredible-bronze-car-73915645
Rating
Price8,500,000.004,000,000.00
Stock

5 in stock

44 in stock

Availability5 in stock44 in stock
Add to cart

View products

Add to cart

Read more

Read more

Add to cart

Read more

DescriptionInfection prevention and control measures include, hand hygiene, personal protective equipment and waste management materials.Internal patient file information management system can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on.The Blood Bank Refrigerator is a specialized refrigerating equipment for blood (whole blood) storage application.The products is designed on the principles basis of Goldman tonometer.Excellent cold light: adopting LED as light source, without temperature rising.Peritoneal dialysis involves surgery to implant a peritoneal dialysis (PD) catheter into your abdomen.
Content

Personal Protective Equipment

Infection prevention and control measures include, hand hygiene, personal protective equipment and waste management materials. The Protective equipment consists of garments placed to protect the health care workers or any other persons to get infected. These usually consist of standard precautions: gloves, mask, gown. If it is blood or airborne high infections, will include: Face protection, goggles and mask or face shield, gloves, gown or coverall, head cover, rubber boots.

Summary of main specifications

1. Trolley type all digital color Doppler ultrasonic mainframe 2. Ultrasonic host operating system: Windows 7 operating system. 3. Spectrum pulse Doppler. 4. Direction energy Doppler. 5. Real time three synchronization. 6. Space composite imaging: the requirement is 3 level, visual adjustable. 7. Organized harmonic imaging technology. 8. 4B imaging mode. 9. One key intelligent optimization. 10. Support multilingual user interface. 11. Monitor: 17 inches, high definition LED 12. Physical clipboard: display the saved image below the screen, which can be deleted directly. 13. The system has the function of on-the-spot upgrade 14. Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. 15. The probe interface is 3   Technical Specifications Probes Convex probe 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz Linear probe 6.0MHz/6.5MHz/7.5MHz/10.0MHz/12.0MHz Trans-vaginal probe 5.0MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz R11 Micro convex probe 5.5MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz R15 Micro convex probe 5.5MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz 4D Volume probe 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz Under each probe, there is a selection of specialist and viscera mode and rapid entry detection. Two-dimensional imaging mode Gain 0-100, step 2 visible adjustable TGC 8 segment adjustable Image optimization visible and adjustable over 6 levels Dynamic range 0-270dB 15 level visual adjustable False color 7, visible and adjustable Smooth treatment 8, visible and adjustable Edge enhancement 8, visible and adjustable Sound power 0-15 stage, step 7%, visible adjustable Display depth ≥320mm Maximum focus number 4 focal points, which can be moved throughout the whole process. Scan line density 256 visible tunable Gray scale 1-16 level visible visible and adjustable Filtering 3 kinds Scanning range 50%-100% Frame correlation 0-4 level, visible and adjustable The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 14 parameters can be adjusted Color imaging mode Color frequency ≥5 frequency conversion, visible adjustable Color deflection equipped with C afterglow 8, visible and adjustable Color map 7, visible and adjustable Color reversal adjustable B/C split screen synchronous display function equipped with Color baseline 7, visible and adjustable Color line density adjustable Spectrum Doppler mode Sampling volume angle correction -80 degree to 80 degree adjustable Sample volume 0.5mm-48mm visually adjustable Frequency ≥ 5, visible and adjustable Baseline 7 adjustable Smooth 8 files can be adjusted False color 7 kinds of adjustable Maximum display blood flow measurement speed 25m/s, minimum resolvable blood flow measurement speed 0.1mm/s Measurement and analysis function General measurement distance, area, angle, time, slope, heart rate, velocity, acceleration, neck hyaline layer, spectrum tracing, resistance index / pulsatility index, etc. Professional software package: abdomen, volume, ratio, obstetrics and Gynecology, small organs, carotid artery, Urology, heart. Graphic and text management system Host built in ≥ 120G solid state hard disk to start fast and stable Movie playback 600 frames Internal patient file information management system can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on. The type of report is 3. Provide picture proof. One key fast report graphic and text management Interface USB interface 2 VGA interface 1 RJ-45 interface 1 VIDEO interface 1 Grounding wire interface 1 Technology, after-sales service and other requirements After acceptance, the warranty is free for two years Manufacturer has ISO13485 certification.

Stainless Steel Blood Bank Refrigerator (+4°C)

  The Blood Bank Refrigerator is a specialized refrigerating equipment for blood (whole blood) storage application, which has been used in medical industries as well as cold storage of pharmaceuticals, biological products, vaccine, and so forth.it is suitable for hospitals, blood banks and sanitation and ant epidemic stations.

Control System:

-Microprocessor-based temperature controller. Temperature range 4±1°C, with temperature printer standard. -Large screen LCD display of temperature, display accuracy of +/- 0.1°C. -Automatic temperature control, Defrost automatic -Audible and visual alarm: High or low temperature alarm, Door ajar alarm, system failure alarm, power failure alarm, low battery alarm. -Power supply: 220V 50Hz 1 phase, can be changed as 220V 60HZ or 110V 50/60HZ  

Structure Design:

-Upright type, Exterior made from painted steel plate, Inside is stainless steel. -Four units Caster are mounted under the bottom -Three-layer glass door with heater around to prevent ice leak, and lockable. -Interior fluorescent light -Inner is shelves (wire plastics). 3units for ABR-88L, 4units for ABR-268L, 5units for ABR-358L, 6units for ABR-588L. -Temperature printer is standard, Optional chart recorder, blood storage basket.  

Refrigeration System:

-Forced air circulation system -International Famous compressor and Germany EBM fan motors -The high-effective air-cooled condenser and the fin-type evaporator -Refrigerant as R134a, CFC free -Certificate: CE mark, ISO9001, ISO14001, ISO13485

Specifications:

 
Model Capacity (L) External size (D*W*H)mm Interior size (D*W*H)mm Blood capacity Weight (KG)
ABR-88L 88 500*450*1515 402*343*663 450ml/bag*40-50/bags 90/100
ABR-268L 268 700*628*1662 512*518*973 450ml/bag*100-140/bags 160/170
ABR-358L 358 700*628*1962 512*515*1270 450ml/bag*180-220/bags 200/210
ABR-588L 588 800*760*1977 550*560*1260 450ml/bag*250-300/bags 230/240

Tonometer

Description

The products is designed on the principles basis of Goldman tonometer. Three types are available: R and T type are suitable for aig streit type slit lamp While X type is suitable for Carl Zeiss type slit lamp.

Specification:

-It is not only used to examine the eyes, but also measure the intraocular pressure while working under the slit lamp. -Accurate measurement ensures the total tolerance less than 0.066KPa (0.5mmHg). -Directly get the intraocular pressure. -Measured intraocular pressure will not be affected by hardness of eye. -Adjustable measuring pressure ensures the working stability and accurate measurement of tonometer for long time.

Features

-Excellent cold light: adopting LED as light source, without temperature rising. -Excellent daylight quality and CRI meet the illumination needs of the doctors. -Long service life: LED life is up to 30,000 hours. -Energy saving and environment-friendly. Technical Specifications

PARAMETER SPECIFICATION

Illuminance ≥100,000Lux Color Temperature 4800±300K Illuminance Depth ≥500mm Size of Light Field 160~220mm Rated Power of Bulb 3.2V/1W (80pc LED bulb) Power Supply Voltage 220V/50Hz LED Bulb Life ≥30,000 hr
Peritoneal dialysis involves surgery to implant a peritoneal dialysis (PD) catheter into your abdomen. The catheter helps filter your blood through the peritoneum, a membrane in your abdomen. During treatment, a special fluid called dialysate flows into the peritoneum. The dialysate absorbs waste. Once the dialysate draws waste out of the bloodstream, it’s drained from your abdomen. This process takes a few hours and needs to be repeated four to six times per day. However, the exchange of fluids can be performed while you’re sleeping or awake. There are numerous different types of peritoneal dialysis. The main ones are:
  • Continuous ambulatory peritoneal dialysis (CAPD). In CAPD, your abdomen is filled and drained multiple times each day. This method doesn’t require a machine and must be performed while awake.
  • Continuous cycling peritoneal dialysis (CCPD). CCPD uses a machine to cycle the fluid in and out of your abdomen. It’s usually done at night while you sleep.
  • Intermittent peritoneal dialysis (IPD). This treatment is usually performed in the hospital, though it may be performed at home. It uses the same machine as CCPD, but the process takes longer.
Weight67 kgN/AN/AN/AN/A129 kg
Dimensions131 × 11 × 160 cmN/AN/AN/AN/A185 × 119 × 173 cm
Additional information
Weight 67 kg
Dimensions 131 × 11 × 160 cm
Inventore

itaque, debitis, in, laborum

Weight 129 kg
Dimensions 185 × 119 × 173 cm