Description | Main Body High-strength engineering plastic rack, light, beautiful and corrosion resistant | advanced lighting equipment at home and abroad. | Excellent cold light: adopting LED as light source, without temperature rising. | The products is designed on the principles basis of Goldman tonometer. | The modern lifestyle has made various health risks such as hypertension, heart disease, and other common cardiovascular conditions increasingly common. Picking the right sphygmomanometer is a smart choice that we should all consider daily, for the good of our healthy bodies. | Attendant Wear, Hospital |
Content | Technical Specifications
PARAMETER SPECIFICATION
Main Body High-strength engineering plastic rack, light, beautiful and corrosion resistant.
Scope of Application Adult, child
Gas Source O2: 0.27--0.55Mpa;
N2O: 0.27--0.55MPa.
Flow Meter O2: 0.1--1.0L/min; 1.1--10L/min
N20: 0.1--1.0L/min; 1.1--10L/min
O2, N2O Linkage and N2O
Stopper When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure < 0.2KPa, the flow of nitrous oxide would be cut off.
Flow Rate of Rapid Oxygen Supply 25--75L/min
Low Oxygen Pressure Alarm There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0-5vol%.
Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
Respiratory Circuit Working mode: all-close, semi-close, semi-open;
APL: 0.5-7kPa.
Respiratory Bellows for adults, bellows for children, tidal volume range:0-1500 ml. | Technical Specifications
Illuminance 30,000Lux 0.5m / 10,000Lux 1m
Color Temperature 4800±200K
Size of Light Field 100mm
Adjust Adjust light
Power Supply Voltage 220V/50Hz
Rated Power of Bulb 3.3V/3W
Crutch Adjust up/down
Bulb LED bulb
Product Features
-YD01A (LED) examination lamp is extensively applied in industry, medical treatment, jewelry, photograph scientific research etc.
-It is currently more advanced lighting equipment at home and abroad. | Features
-Excellent cold light: adopting LED as light source, without temperature rising.
-Excellent daylight quality and CRI meet the illumination needs of the doctors.
-Long service life: LED life is up to 30,000 hours.
-Energy saving and environment-friendly.
Technical Specifications
PARAMETER SPECIFICATION
Illuminance ≥100,000Lux
Color Temperature 4800±300K
Illuminance Depth ≥500mm
Size of Light Field 160~220mm
Rated Power of Bulb 3.2V/1W (80pc LED bulb)
Power Supply Voltage 220V/50Hz
LED Bulb Life ≥30,000 hr | Tonometer
Description:
The products is designed on the principles basis of Goldman tonometer.
Three types are available: R and T type are suitable for aig streit type slit lamp
While X type is suitable for Carl Zeiss type slit lamp.
Specification:
-It is not only used to examine the eyes, but also measure the intraocular pressure while working under the slit lamp.
-Accurate measurement ensures the total tolerance less than 0.066KPa (0.5mmHg).
-Directly get the intraocular pressure.
-Measured intraocular pressure will not be affected by hardness of eye.
-Adjustable measuring pressure ensures the working stability and accurate measurement of tonometer for long time. | Aneroid Sphygmomanometer
Say the words “aneroid sphygmomanometer” to most people in the country, and they will look at you confused. Say them to any person in the medical community, and they will immediately know you are talking about a blood pressure monitoring device. Aneroid sphygmomanometers are comprised of an inflatable cuff that collapses then releases the artery under the cuff in a precisely controlled manner.
Inside of the device, a mercury or mechanical manometer is used to measure the pressure in conjunction with a device to measure the pressure where blood flow is just starting and at what pressure it is unimpeded. Manual aneroid sphygmomanometers are used with a stethoscope to hear these points.
Product Features
- Needs and Price: The right sphygmomanometer is determined by the needs and requirements of its user.
- Accuracy: As with any medical instrument, the accuracy of measurements is of utmost importance.
- Quality, Design, and Cuff Size: Sphygmomanometers vary according to their quality of material and design, all of which affect the overall performance of the device.
| Product Specification
Size: All Sizes
Category: Doctor General Wear, Nurse Wear, Attendant Wear, Hospital Staff Wear
Material: All Materials
Type: Stitched
Sleeve Type: Long
Gender: Unisex
Usage: Hospital
Minimum Order Quantity: 50 Piece
All Colours Available |