Content | Technical Specifications
Illuminance 30,000Lux 0.5m / 10,000Lux 1m
Color Temperature 4800±200K
Size of Light Field 100mm
Adjust Adjust light
Power Supply Voltage 220V/50Hz
Rated Power of Bulb 3.3V/3W
Crutch Adjust up/down
Bulb LED bulb
Product Features
-YD01A (LED) examination lamp is extensively applied in industry, medical treatment, jewelry, photograph scientific research etc.
-It is currently more advanced lighting equipment at home and abroad. | Personal Protective Equipment
Infection prevention and control measures include, hand hygiene, personal protective equipment and waste management materials.
The Protective equipment consists of garments placed to protect the health care workers or any other persons to get infected.
These usually consist of standard precautions: gloves, mask, gown. If it is blood or airborne high infections, will include: Face protection, goggles and mask or face shield, gloves, gown or coverall, head cover, rubber boots. | ARI-800B+ Patient Monitor
15 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
1.13 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
- Efficient resistance to interference of defibrillator and electrosurgical cautery;
- SPO2 can testing for 0.1% Weak;
- RA-LL impedance Respiration;
- Trend Coexist Display;
- Oxy-CRG Dynamic View Display;
- Bed to Bed view Display;
- Networking capacity and nurse calling system;
- Options of printing, IBP, VGA and EtCO2;
- UP to 4 hours working capacity of built-in rechargeable battery;
11.15" high resolution color TFT LCD display;
- Large volume of tabular and graphic trends information storage and easy to recall;
- Anti-ESU, anti- defibrillator;
- Capture dynamic waveforms.
Technical specification: ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2ch
Lead mode: 3 Leads (R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1ch
Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
HR and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10uA
Baseline Recovery: < 3 S after Defi.
ECG Signal Range: ±8 m V (Vp-p)
Bandwidth
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p), Accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
RESPIRATION
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: 10 ~ 40 S
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN: 20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100 mmHg
MEAN: 20 ~ 110 mmHg
Resolution Pressure: 1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg
SpO2
Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy: ±2bpm
TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy: ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant: <10 Sec.
IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor
Sensitivity: 5uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec
Standard Packing List:
5-lead ECG cable (including RESP)
Adult finger SpO2 sensor
Adult NIBP cuff
NIBP extension tube
TEMP sensor
AC power adaptor
ECG electrodes
Operation instruction
Selectable Accessory:
Child finger SPO2 sensor
Child NIBP cuff
Neonate NIBP cuff | Quick Details
Type: Hospital Furniture
Specific Use: Hospital Table
General Use: Commercial Furniture
Material: Metal
Metal Type: Stainless Steel
Folded: No
Size: 600*400*750-1050mm
Brand Name: WCM
Model Number: WCM-F-F124
Product Name: Stainless Steel Mayo Table Operation Instrument Trolley
Color: customizable
Feature: Adjustable
Accessories: wheels
| Aneroid Sphygmomanometer
Say the words “aneroid sphygmomanometer” to most people in the country, and they will look at you confused. Say them to any person in the medical community, and they will immediately know you are talking about a blood pressure monitoring device. Aneroid sphygmomanometers are comprised of an inflatable cuff that collapses then releases the artery under the cuff in a precisely controlled manner.
Inside of the device, a mercury or mechanical manometer is used to measure the pressure in conjunction with a device to measure the pressure where blood flow is just starting and at what pressure it is unimpeded. Manual aneroid sphygmomanometers are used with a stethoscope to hear these points.
Product Features
- Needs and Price: The right sphygmomanometer is determined by the needs and requirements of its user.
- Accuracy: As with any medical instrument, the accuracy of measurements is of utmost importance.
- Quality, Design, and Cuff Size: Sphygmomanometers vary according to their quality of material and design, all of which affect the overall performance of the device.
| Tonometer
Description:
The products is designed on the principles basis of Goldman tonometer.
Three types are available: R and T type are suitable for aig streit type slit lamp
While X type is suitable for Carl Zeiss type slit lamp.
Specification:
-It is not only used to examine the eyes, but also measure the intraocular pressure while working under the slit lamp.
-Accurate measurement ensures the total tolerance less than 0.066KPa (0.5mmHg).
-Directly get the intraocular pressure.
-Measured intraocular pressure will not be affected by hardness of eye.
-Adjustable measuring pressure ensures the working stability and accurate measurement of tonometer for long time. |
Reviews
There are no reviews yet.