Content | Technical Specifications
Illuminance 30,000Lux 0.5m / 10,000Lux 1m
Color Temperature 4800±200K
Size of Light Field 100mm
Adjust Adjust light
Power Supply Voltage 220V/50Hz
Rated Power of Bulb 3.3V/3W
Crutch Adjust up/down
Bulb LED bulb
Product Features
-YD01A (LED) examination lamp is extensively applied in industry, medical treatment, jewelry, photograph scientific research etc.
-It is currently more advanced lighting equipment at home and abroad. | Tonometer
Description:
The products is designed on the principles basis of Goldman tonometer.
Three types are available: R and T type are suitable for aig streit type slit lamp
While X type is suitable for Carl Zeiss type slit lamp.
Specification:
-It is not only used to examine the eyes, but also measure the intraocular pressure while working under the slit lamp.
-Accurate measurement ensures the total tolerance less than 0.066KPa (0.5mmHg).
-Directly get the intraocular pressure.
-Measured intraocular pressure will not be affected by hardness of eye.
-Adjustable measuring pressure ensures the working stability and accurate measurement of tonometer for long time. | Summary of main specifications
1. Trolley type all digital color Doppler ultrasonic mainframe
2. Ultrasonic host operating system: Windows 7 operating system.
3. Spectrum pulse Doppler.
4. Direction energy Doppler.
5. Real time three synchronization.
6. Space composite imaging: the requirement is 3 level, visual adjustable.
7. Organized harmonic imaging technology.
8. 4B imaging mode.
9. One key intelligent optimization.
10. Support multilingual user interface.
11. Monitor: 17 inches, high definition LED
12. Physical clipboard: display the saved image below the screen, which can be deleted directly.
13. The system has the function of on-the-spot upgrade
14. Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation.
15. The probe interface is 3
Technical Specifications
Probes
Convex probe 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz
Linear probe 6.0MHz/6.5MHz/7.5MHz/10.0MHz/12.0MHz
Trans-vaginal probe 5.0MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz
R11 Micro convex probe 5.5MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz
R15 Micro convex probe 5.5MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz
4D Volume probe 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz
Under each probe, there is a selection of specialist and viscera mode and rapid entry detection.
Two-dimensional imaging mode
Gain 0-100, step 2 visible adjustable
TGC 8 segment adjustable
Image optimization visible and adjustable over 6 levels
Dynamic range 0-270dB 15 level visual adjustable
False color 7, visible and adjustable
Smooth treatment 8, visible and adjustable
Edge enhancement 8, visible and adjustable
Sound power 0-15 stage, step 7%, visible adjustable
Display depth ≥320mm
Maximum focus number 4 focal points, which can be moved throughout the whole process.
Scan line density 256 visible tunable
Gray scale 1-16 level visible visible and adjustable
Filtering 3 kinds
Scanning range 50%-100%
Frame correlation 0-4 level, visible and adjustable
The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 14 parameters can be adjusted
Color imaging mode
Color frequency ≥5 frequency conversion, visible adjustable
Color deflection equipped with
C afterglow 8, visible and adjustable
Color map 7, visible and adjustable
Color reversal adjustable
B/C split screen synchronous display function equipped with
Color baseline 7, visible and adjustable
Color line density adjustable
Spectrum Doppler mode
Sampling volume angle correction -80 degree to 80 degree adjustable
Sample volume 0.5mm-48mm visually adjustable
Frequency ≥ 5, visible and adjustable
Baseline 7 adjustable
Smooth 8 files can be adjusted
False color 7 kinds of adjustable
Maximum display blood flow measurement speed 25m/s, minimum resolvable blood flow measurement speed 0.1mm/s
Measurement and analysis function General measurement distance, area, angle, time, slope, heart rate, velocity, acceleration, neck hyaline layer, spectrum tracing, resistance index / pulsatility index, etc.
Professional software package: abdomen, volume, ratio, obstetrics and Gynecology, small organs, carotid artery, Urology, heart.
Graphic and text management system
Host built in ≥ 120G solid state hard disk to start fast and stable
Movie playback 600 frames
Internal patient file information management system can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on.
The type of report is 3. Provide picture proof.
One key fast report graphic and text management
Interface
USB interface 2
VGA interface 1
RJ-45 interface 1
VIDEO interface 1
Grounding wire interface 1
Technology, after-sales service and other requirements
After acceptance, the warranty is free for two years
Manufacturer has ISO13485 certification. | ARI-800B+ Patient Monitor
15 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
1.13 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
- Efficient resistance to interference of defibrillator and electrosurgical cautery;
- SPO2 can testing for 0.1% Weak;
- RA-LL impedance Respiration;
- Trend Coexist Display;
- Oxy-CRG Dynamic View Display;
- Bed to Bed view Display;
- Networking capacity and nurse calling system;
- Options of printing, IBP, VGA and EtCO2;
- UP to 4 hours working capacity of built-in rechargeable battery;
11.15" high resolution color TFT LCD display;
- Large volume of tabular and graphic trends information storage and easy to recall;
- Anti-ESU, anti- defibrillator;
- Capture dynamic waveforms.
Technical specification: ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2ch
Lead mode: 3 Leads (R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1ch
Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
HR and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10uA
Baseline Recovery: < 3 S after Defi.
ECG Signal Range: ±8 m V (Vp-p)
Bandwidth
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p), Accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
RESPIRATION
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: 10 ~ 40 S
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN: 20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100 mmHg
MEAN: 20 ~ 110 mmHg
Resolution Pressure: 1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg
SpO2
Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy: ±2bpm
TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy: ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant: <10 Sec.
IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor
Sensitivity: 5uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec
Standard Packing List:
5-lead ECG cable (including RESP)
Adult finger SpO2 sensor
Adult NIBP cuff
NIBP extension tube
TEMP sensor
AC power adaptor
ECG electrodes
Operation instruction
Selectable Accessory:
Child finger SPO2 sensor
Child NIBP cuff
Neonate NIBP cuff | Product Description
We offer the top range of Drip Stand for our valued patrons. These products are used in numerous purposes in the market.
Product Specification
Primary Material Stainless Steel
Material Grade SS-202
Minimum Height 50 inch
Pipe Diameter 1.25 inch | Product Specification
Brand FABMEDICALS
Shape of Framework Rectangular
Thickness of Mattress 5 cm
Mattress Material PVC
Mattress Color Black
Product Features
· Overall Size: 180 (L) x 60 (W) x 46Hcms.
· Frame work made of Rectangular / Square M.S. Tube
· Back rest section adjustable on Ratchet / Lever
· Legs fitted with PVC Stumps
· 5cm foam cushioned top covered with rexine and perineal cut
· Adjustable lithotomic poles with straps
· Finish: Epoxy powder coated
Additional Information
Delivery Time As per buyer
Port Of Dispatch New Delhi
Production Capacity 5000 units per month
Packaging Details Standard export packing
Payment Terms L/C (Letter of Credit)/T/T (Bank Transfer)/D/P/D/A |
Reviews