Description | Stainless Steel Mayo Table Operation Instrument Trolley | This machine is used to photograph patient's chest, stomach, lumbar and extremity. | Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. | The products is designed on the principles basis of Goldman tonometer. | Main Body High-strength engineering plastic rack, light, beautiful and corrosion resistant | The modern lifestyle has made various health risks such as hypertension, heart disease, and other common cardiovascular conditions increasingly common. Picking the right sphygmomanometer is a smart choice that we should all consider daily, for the good of our healthy bodies. |
Content | Quick Details
Type: Hospital Furniture
Specific Use: Hospital Table
General Use: Commercial Furniture
Material: Metal
Metal Type: Stainless Steel
Folded: No
Size: 600*400*750-1050mm
Brand Name: WCM
Model Number: WCM-F-F124
Product Name: Stainless Steel Mayo Table Operation Instrument Trolley
Color: customizable
Feature: Adjustable
Accessories: wheels
| High Frequency X-ray Radiography System
This machine is used to photograph patient's chest, stomach, lumbar and extremity.
Features:
- It is installed with close-table graphical colorful LCD touch screen, wireless remote control exposure, make the operator easy to use.
- We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low, to protect the patient better.
- Adopt the technology of kV and mAs numeral Closed loop control, Real-time control of the microprocessor, which ensure the accuracy and repeatability of the output dose.
4.Be equipped with radiography parameter of multi-part, multi-posture, multi-body type’s adult ,child physical characteristic, the operator can modify and save the parameter by himself, which make the operation more conveniently.
- Possess multiple automatic protection and fault clue function, make the operation more safe and reliable.
- The radiography table can float in any direction, electromagnetic braking, position the patient more convenience and accuracy.
7. X-ray generator component can move round the axis of X-ray generator, crossarm and Pillar stand , be convenient with side and slanting direction projection and radiography of patient on the stretcher.
- Be equipped with the bucky stand, which is used in the radiography of the head, chest, belly, pelvic cavity, backbone and periphery.
- Control console of graphic program controlled LCD touch screen is optional, which can set the radiography parameter and exposure in another room.
Specifications
Power Output |
25kW |
Main Inverted Frequency |
40kHz |
X-ray Tube |
Focus |
Big Focus |
1.0 |
Small Focus |
0.3 |
Thermal Capacity |
212kJ (300kHU) |
Speed of Rotary Anode |
3000rpm |
Tube Current |
200mA |
Tube Voltage |
40~125kV |
mAs |
0.4~360mAs |
Bucky Grid |
Grid Density |
103/INCH |
Grid Ratio |
10:1 |
Focus Distance |
120cm |
|
Stationary 18” ×18” |
Power Supply |
380V, 50Hz/60Hz
Capacity: ≥30kVA |
Operation Method |
Graphic Touch-screen LCD
Wireless remote-control exposure |
Option |
Console of graphic touch-screen LCD |
| Product Specification
Size 1830 mm L X 560 mm W X 810 mm H
Brand FABMEDICALS
Overall Dimension 1830 mm X 560 mm X 810 mm H
Height Adjustable NO
Storage Option NO
Finish Epoxy Powder Coated
Warranty One year
Finish Type Epoxy powder coated
Frame Type CRCA
Color Black
Product Features
Over all Approx. Dimension: 1830 mm L x 560 mm W x 810 mm H
Three section top with fix mattress
U Cut in center part
Backrest and Knee rest movement on ratchet
Lithotomy rod and SS bowl
Pretreated and powder coated
Additional Information
Production Capacity 200 per month | Tonometer
Description:
The products is designed on the principles basis of Goldman tonometer.
Three types are available: R and T type are suitable for aig streit type slit lamp
While X type is suitable for Carl Zeiss type slit lamp.
Specification:
-It is not only used to examine the eyes, but also measure the intraocular pressure while working under the slit lamp.
-Accurate measurement ensures the total tolerance less than 0.066KPa (0.5mmHg).
-Directly get the intraocular pressure.
-Measured intraocular pressure will not be affected by hardness of eye.
-Adjustable measuring pressure ensures the working stability and accurate measurement of tonometer for long time. | Technical Specifications
PARAMETER SPECIFICATION
Main Body High-strength engineering plastic rack, light, beautiful and corrosion resistant.
Scope of Application Adult, child
Gas Source O2: 0.27--0.55Mpa;
N2O: 0.27--0.55MPa.
Flow Meter O2: 0.1--1.0L/min; 1.1--10L/min
N20: 0.1--1.0L/min; 1.1--10L/min
O2, N2O Linkage and N2O
Stopper When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure < 0.2KPa, the flow of nitrous oxide would be cut off.
Flow Rate of Rapid Oxygen Supply 25--75L/min
Low Oxygen Pressure Alarm There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0-5vol%.
Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
Respiratory Circuit Working mode: all-close, semi-close, semi-open;
APL: 0.5-7kPa.
Respiratory Bellows for adults, bellows for children, tidal volume range:0-1500 ml. | Aneroid Sphygmomanometer
Say the words “aneroid sphygmomanometer” to most people in the country, and they will look at you confused. Say them to any person in the medical community, and they will immediately know you are talking about a blood pressure monitoring device. Aneroid sphygmomanometers are comprised of an inflatable cuff that collapses then releases the artery under the cuff in a precisely controlled manner.
Inside of the device, a mercury or mechanical manometer is used to measure the pressure in conjunction with a device to measure the pressure where blood flow is just starting and at what pressure it is unimpeded. Manual aneroid sphygmomanometers are used with a stethoscope to hear these points.
Product Features
- Needs and Price: The right sphygmomanometer is determined by the needs and requirements of its user.
- Accuracy: As with any medical instrument, the accuracy of measurements is of utmost importance.
- Quality, Design, and Cuff Size: Sphygmomanometers vary according to their quality of material and design, all of which affect the overall performance of the device.
|
Reviews
There are no reviews yet.