Content | Technical Specifications
PARAMETER SPECIFICATION
Main Body High-strength engineering plastic rack, light, beautiful and corrosion resistant.
Scope of Application Adult, child
Gas Source O2: 0.27--0.55Mpa;
N2O: 0.27--0.55MPa.
Flow Meter O2: 0.1--1.0L/min; 1.1--10L/min
N20: 0.1--1.0L/min; 1.1--10L/min
O2, N2O Linkage and N2O
Stopper When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure < 0.2KPa, the flow of nitrous oxide would be cut off.
Flow Rate of Rapid Oxygen Supply 25--75L/min
Low Oxygen Pressure Alarm There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0-5vol%.
Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
Respiratory Circuit Working mode: all-close, semi-close, semi-open;
APL: 0.5-7kPa.
Respiratory Bellows for adults, bellows for children, tidal volume range:0-1500 ml. | Summary of main specifications
1. Trolley type all digital color Doppler ultrasonic mainframe
2. Ultrasonic host operating system: Windows 7 operating system.
3. Spectrum pulse Doppler.
4. Direction energy Doppler.
5. Real time three synchronization.
6. Space composite imaging: the requirement is 3 level, visual adjustable.
7. Organized harmonic imaging technology.
8. 4B imaging mode.
9. One key intelligent optimization.
10. Support multilingual user interface.
11. Monitor: 17 inches, high definition LED
12. Physical clipboard: display the saved image below the screen, which can be deleted directly.
13. The system has the function of on-the-spot upgrade
14. Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation.
15. The probe interface is 3
Technical Specifications
Probes
Convex probe 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz
Linear probe 6.0MHz/6.5MHz/7.5MHz/10.0MHz/12.0MHz
Trans-vaginal probe 5.0MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz
R11 Micro convex probe 5.5MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz
R15 Micro convex probe 5.5MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz
4D Volume probe 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz
Under each probe, there is a selection of specialist and viscera mode and rapid entry detection.
Two-dimensional imaging mode
Gain 0-100, step 2 visible adjustable
TGC 8 segment adjustable
Image optimization visible and adjustable over 6 levels
Dynamic range 0-270dB 15 level visual adjustable
False color 7, visible and adjustable
Smooth treatment 8, visible and adjustable
Edge enhancement 8, visible and adjustable
Sound power 0-15 stage, step 7%, visible adjustable
Display depth ≥320mm
Maximum focus number 4 focal points, which can be moved throughout the whole process.
Scan line density 256 visible tunable
Gray scale 1-16 level visible visible and adjustable
Filtering 3 kinds
Scanning range 50%-100%
Frame correlation 0-4 level, visible and adjustable
The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 14 parameters can be adjusted
Color imaging mode
Color frequency ≥5 frequency conversion, visible adjustable
Color deflection equipped with
C afterglow 8, visible and adjustable
Color map 7, visible and adjustable
Color reversal adjustable
B/C split screen synchronous display function equipped with
Color baseline 7, visible and adjustable
Color line density adjustable
Spectrum Doppler mode
Sampling volume angle correction -80 degree to 80 degree adjustable
Sample volume 0.5mm-48mm visually adjustable
Frequency ≥ 5, visible and adjustable
Baseline 7 adjustable
Smooth 8 files can be adjusted
False color 7 kinds of adjustable
Maximum display blood flow measurement speed 25m/s, minimum resolvable blood flow measurement speed 0.1mm/s
Measurement and analysis function General measurement distance, area, angle, time, slope, heart rate, velocity, acceleration, neck hyaline layer, spectrum tracing, resistance index / pulsatility index, etc.
Professional software package: abdomen, volume, ratio, obstetrics and Gynecology, small organs, carotid artery, Urology, heart.
Graphic and text management system
Host built in ≥ 120G solid state hard disk to start fast and stable
Movie playback 600 frames
Internal patient file information management system can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on.
The type of report is 3. Provide picture proof.
One key fast report graphic and text management
Interface
USB interface 2
VGA interface 1
RJ-45 interface 1
VIDEO interface 1
Grounding wire interface 1
Technology, after-sales service and other requirements
After acceptance, the warranty is free for two years
Manufacturer has ISO13485 certification. | Product features
BFV-263 two kinds of imaging mode, one-click switching freely, Auto-sleep function.
Two kinds of imaging modes: blue & white, red & green, one-click switching freely;
Image performance optimization, adjustable brightness, high accurate;
Medical cold light, safe for your eyes;
Sleep function, more comfortable operation elegant design, easy to carry.
Product description
Vein finder is developed by Best man Instrument independently. It is non-contact imaging device of subcutaneous vein and belongs to the internal power supply equipment. It uses the safety cold light, positioning the subcutaneous veins on the surface of patient's skin. BVF-260 is easy to detect veins at the back of the hands through transmission of LED red light and it can assist medical staff to observe sub-cutaneous veins of hands and significantly improve the success rate of the injection It is suitable for hospitals, Clinics, homes as well as any other places to find the veins for injection. | Personal Protective Equipment
Infection prevention and control measures include, hand hygiene, personal protective equipment and waste management materials.
The Protective equipment consists of garments placed to protect the health care workers or any other persons to get infected.
These usually consist of standard precautions: gloves, mask, gown. If it is blood or airborne high infections, will include: Face protection, goggles and mask or face shield, gloves, gown or coverall, head cover, rubber boots. | Technical Specifications
Illuminance 30,000Lux 0.5m / 10,000Lux 1m
Color Temperature 4800±200K
Size of Light Field 100mm
Adjust Adjust light
Power Supply Voltage 220V/50Hz
Rated Power of Bulb 3.3V/3W
Crutch Adjust up/down
Bulb LED bulb
Product Features
-YD01A (LED) examination lamp is extensively applied in industry, medical treatment, jewelry, photograph scientific research etc.
-It is currently more advanced lighting equipment at home and abroad. | BVF-260
It is non-contact imaging device of subcutaneous vein and belongs to the internal power supply equipment. It uses the safety cold light, positioning the subcutaneous veins on the surface of patient's skin. BVF-260 is easy to detect veins at the back of the hands through transmission of LED red light and it can assist medical staff to observe sub-cutaneous veins of hands and significantly improve the success rate of the injection It is suitable for hospitals, Clinics, homes as well as any other places to find the veins for injection.
Vein Finder Function
The majority of people have highly visible veins, which enable health care providers to perform fast and accurate venous punctures. However, veins are not always visible in children because of fatty tissue. They are also difficult to locate in the elderly, in people having dark complexions or obese patients. In these instances, vein finders are beneficial to patients and medical caregivers alike.
Blood contains oxygen and nutrient-carrying hemoglobin molecules, which readily absorb infrared light. When an active infrared vein finder is applied to the skin, the vessels become visible to the naked eye, as the absorbed light in the hemoglobin make the veins appear darker, which is in high contrast compared to surrounding tissue.
Vein finding devices vary in capability. Some emit lightwaves that penetrate a few millimeters into the skin. The devices make superficial blood vessels easy to locate. Other devices emit lightwaves at higher intensities, which provide detection of deeper veins.
Passive vein finders are another option. Instead of using infrared light absorption, the eyewear devices alter the light that caregivers see by using specially filtered lenses.
What to Look for in a Vein Finder
There are a few important things that you should look for/keep in mind when searching for a vein finder.
Is it Intended for Adults or Children?
While most models can be used on both, some are usually only intended to be used on one. A vein finder that is made for children has a much lower LED light effect which is not good for adults who need more light in order to see their veins. It’s important to make sure to check before buying one to make sure you get the correct model.
Does it Have a Rechargeable Battery?
If you intend to buy an active vein finder you want to make sure it has a rechargeable battery. This can help to make sure that you don’t have to constantly keep investing in new batteries all the time in order for it to work.
It’s also a good idea to check to see how many battery packs a vein finder comes with. If it comes with one it would be good to have another one on hand that you can charge and quickly swap with the current battery pack when that certain pack needs to be recharged.
Does it Highlight Facial Veins?
Finding facial veins can be a very difficult and delicate thing for vein finders to do. Because of this, some models don’t work well with highlighting facial veins. If you intend to use a vein finder on the face, it’s a good idea to check to make sure if it has the ability to do so.
Can it be Cleaned?
Cleaning a vein finder is very important, especially if you intended to use the same product on multiple people. You want to make sure that the vein finder can be easily sanitized and won’t end up somehow damaging the product if you do so.
A Light Shield
While some vein finder models are made with a light that isn’t too irritating, some do come with very strong lights. These lights can end up irritating your eyes which will hurt them because they are so bright and strong. A light shield can help to protect your eyes when using one and can also help you to better see any veins that might show up with the device. |