Features:<\/strong><\/b><\/p>\n New appearance, There are three large size full color LCD screen on the machine, and one 8 inch LCD touch screen on the console.<\/p>\n Main Parameters:<\/strong><\/b><\/p>\n Three different X-ray tubes to choose:<\/p>\n — Hangzhou LR01 tube from China<\/p>\n — IAE C339V tube from Italy<\/p>\n — VARIAN B115 tube from America<\/p>\n Complete solid-state high-frequency high-voltage generator.<\/p>\n Generator Type: High Frequency Inverter 80kHz<\/p>\n Input Power: Single phase 220VAC, 50\/60Hz<\/p>\n Radiographic Ratings: Large Focal Point 20-35kV\/10-510mAs<\/p>\n Small Focal Point 20-35kV\/10-100mAs<\/p>\n Power Rating: 6.2kW<\/p>\n 1) Hangzhou LR01 tube from China<\/strong><\/p>\n Focal Spot Size\uff1a Dual Focus 0.2 \/ 0.4mm<\/p>\n Target Material\uff1aMolybdenum (Mo)<\/p>\n Port Material\uff1aBeryllium (Be)<\/p>\n High-speed anode drive: 2800\/1000rpm<\/p>\n Target angle: 12\u00b0\/12\u00b0<\/p>\n Anode Heat Storage\uff1a 100KJ (150kHU)<\/p>\n Anode Cooling\uff1aAir cooling<\/p>\n Filtration\uff1a Mo\uff080.03mm\uff09\uff0cAl\uff080.5mm\uff09<\/p>\n 2) <\/strong><\/b>IAE C339V tube from Italy<\/strong><\/b><\/p>\n Focal Spot Size: Dual Focus 0.1\/0.3mm<\/p>\n Target Material: Molybdenum (Mo)<\/p>\n Port Material: Beryllium (Be)<\/p>\n High-speed anode drive: 2800\/1000rpm<\/p>\n Target angle: 10\u00b0\/16\u00b0<\/p>\n Anode Heat Storage: 210kJ (300kHU)<\/p>\n Anode Cooling: Air cooling<\/p>\n Filtration: Mo(0.03mm), Al(0.5mm)<\/p>\n 3) <\/strong><\/b>VARIAN B115 tube from America<\/strong><\/b><\/p>\n Focal Spot Size: Dual Focus 0.1\/0.3mm<\/p>\n Target Material: Molybdenum (Mo)<\/p>\n Port Material: Beryllium (Be)<\/p>\n High-speed anode drive: 2800\/1000rpm<\/p>\n Target angle: 10\u00b0\/16\u00b0<\/p>\n Anode Heat Storage: 210kJ (300kHU)<\/p>\n Anode Cooling: Air cooling<\/p>\n Filtration: Mo(0.03mm),Al(0.5mm)<\/p>\n C-ARM: Vertical Movement: 590mm<\/p>\n Center of electric rotating C-arm, automatic return function by one key<\/p>\n Automatically released after the exposure pressure settings display<\/p>\n Compression flexible stepless speed.<\/p>\n Max. pressure: 200N<\/p>\n Max. travel: 150mm<\/p>\n Rotations Deg:+90\u00b0~-90\u00b0<\/p>\n SID: 650mm<\/p>\n 18*24cm (24cm*30cm optional)<\/p>\n Bucky Device: 18*24cm Bucky drive mechanism,(24cm*30cm optional)<\/p>\n Grid Ratio: 5:1, 30 Line\/cm<\/p>\n 220Vac@25A, Single phase<\/p>\n 240kg(Gross weight: 340kg)<\/p>\n L*W\u00d7H: 940mm*560mm*2000mm<\/p>\n Upgrading:<\/strong><\/b><\/p>\n Above introduction for ARI-9800D is an analog mammography, actually, it can be upgraded into a DR system. Here is the main parameters for digital mammography.<\/p>\n New appearance, There are three large size full color LCD screen on the machine, and one 8 inch LCD touch screen on the console.<\/p>\n","protected":false},"featured_media":8320,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false},"product_cat":[46,77],"product_tag":[53],"class_list":{"0":"post-181","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-diagnostic-equipment","7":"product_cat-x-ray-series","8":"product_tag-repellendus","10":"first","11":"instock","12":"shipping-taxable","13":"purchasable","14":"product-type-variable"},"yoast_head":"\n\n
\n
\n
\n
\n
\n
\n\n
\n Main Parameters for Full Digital Mammography System<\/td>\n<\/tr>\n \n Name<\/td>\n Parameters<\/td>\n<\/tr>\n \n Specialized Digital Flat Panel Detector for Mammography<\/td>\n Detector, Power Box, Date Line, Capture Card, etc<\/td>\n<\/tr>\n \n Effective Coverage of Detector<\/td>\n 23*15cm, 29*23cm<\/td>\n<\/tr>\n \n Pixel Matrix<\/td>\n 3072*1944, 3888*3072<\/td>\n<\/tr>\n \n Limit of Spatial Resolution<\/td>\n 6.0Lp\/mm<\/td>\n<\/tr>\n \n DQE Value<\/td>\n 70%<\/td>\n<\/tr>\n \n Dynamic Range<\/td>\n 14bit digital output<\/td>\n<\/tr>\n \n Pixel Size<\/td>\n 75um<\/td>\n<\/tr>\n \n High Voltage Synchronizer<\/td>\n BNC<\/td>\n<\/tr>\n \n Output<\/td>\n Camera Link or Ethernet<\/td>\n<\/tr>\n \n Working Condition<\/td>\n 10-40\u2103<\/td>\n<\/tr>\n \n Storage Environment<\/td>\n -10-50\u2103<\/td>\n<\/tr>\n \n Bucky<\/td>\n Housing and Movement Device<\/td>\n<\/tr>\n \n Size<\/td>\n 370*275*125cm<\/td>\n<\/tr>\n \n Stepless Speed Regulating Range<\/td>\n 0-6cm\/s<\/td>\n<\/tr>\n \n Movement Range<\/td>\n 0.5-2cm<\/td>\n<\/tr>\n \n Grid<\/td>\n<\/tr>\n \n Size<\/td>\n 24*30cm<\/td>\n<\/tr>\n \n Grid Ratio<\/td>\n 3.5:1<\/td>\n<\/tr>\n \n Focal Distance<\/td>\n 65cm<\/td>\n<\/tr>\n \n Software<\/td>\n<\/tr>\n \n Workstation<\/td>\n Standard Detector Image Acquisition Workstation<\/td>\n<\/tr>\n \n CPU\u2265Intel Duo Core 2.60GHz<\/td>\n<\/tr>\n \n Hardware\u2265250G<\/td>\n<\/tr>\n \n Memory\u22652G<\/td>\n<\/tr>\n \n Display Card\u2265512MB<\/td>\n<\/tr>\n \n 19\u2019\u2019 High Brightness High Contrast LCD, 1280*1024 Pixel Resolution<\/td>\n<\/tr>\n \n Network Interface Worklist<\/td>\n<\/tr>\n \n DICOM3.0 Transmission<\/td>\n<\/tr>\n \n 100\/1000 Gigabit Ethernet<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"