Content | Portable Digital Slit Lamp
AME-5S3 Portable Digital Slit Lamp Microscope is produced with high illumination white LED, and can be used about 5 to 6 hours continuously after fully recharged. The net weight is 750 g only, so that very convenient to be carried. And very proud that it is the very initial and most advanced portable model in China. With Nikon Camera & Camera adaptor & Background illumination & Fixation Lamp
Microscope type: Binocular crossed stereo microscope
Total Magnification:
|
10 x Eyepiece |
16 x Eyepiece |
1 x Objective |
10 |
16 |
Diopter compensation:-7D~+7D
Working distance: 80mm
Slit width: 0~10mm continuously adjustable
Slit height: 1mm, 3mm, 5mm, 10mm
Diameter of light spot: 1mm, 3mm, 5mm, 10mm
Filter: heating absorption, 50%ND, Red-free, blue
Illumination Rotate Angle: horizontal ±30 degree
Illumination: White LED
Input Voltage: AC 100~240V, 60~50HZ
Input Power: 18VA
| Peritoneal dialysis involves surgery to implant a peritoneal dialysis (PD) catheter into your abdomen. The catheter helps filter your blood through the peritoneum, a membrane in your abdomen. During treatment, a special fluid called dialysate flows into the peritoneum. The dialysate absorbs waste. Once the dialysate draws waste out of the bloodstream, it’s drained from your abdomen.
This process takes a few hours and needs to be repeated four to six times per day. However, the exchange of fluids can be performed while you’re sleeping or awake.
There are numerous different types of peritoneal dialysis. The main ones are:
- Continuous ambulatory peritoneal dialysis (CAPD). In CAPD, your abdomen is filled and drained multiple times each day. This method doesn’t require a machine and must be performed while awake.
- Continuous cycling peritoneal dialysis (CCPD). CCPD uses a machine to cycle the fluid in and out of your abdomen. It’s usually done at night while you sleep.
- Intermittent peritoneal dialysis (IPD). This treatment is usually performed in the hospital, though it may be performed at home. It uses the same machine as CCPD, but the process takes longer.
| Main Features
1. Adopt 1/2.8inch SONY CMOS HD camera.
2. With 2,100,000 total pixels, 1920*1080p image size and TV line 1080lines
3. Professional video out: CVBS, S-VIDEO, DVI, HDMI
4. 5inch LCD screen
5. Suggest to be used for laparoscope, hysteroscope etc.
Image show
| Mammography System
Features:
New appearance, There are three large size full color LCD screen on the machine, and one 8 inch LCD touch screen on the console.
Main Parameters:
Three different X-ray tubes to choose:
-- Hangzhou LR01 tube from China
-- IAE C339V tube from Italy
-- VARIAN B115 tube from America
- X-ray Generator
Complete solid-state high-frequency high-voltage generator.
Generator Type: High Frequency Inverter 80kHz
Input Power: Single phase 220VAC, 50/60Hz
Radiographic Ratings: Large Focal Point 20-35kV/10-510mAs
Small Focal Point 20-35kV/10-100mAs
Power Rating: 6.2kW
- X-ray Tube
1) Hangzhou LR01 tube from China
Focal Spot Size: Dual Focus 0.2 / 0.4mm
Target Material:Molybdenum (Mo)
Port Material:Beryllium (Be)
High-speed anode drive: 2800/1000rpm
Target angle: 12°/12°
Anode Heat Storage: 100KJ (150kHU)
Anode Cooling:Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
2) IAE C339V tube from Italy
Focal Spot Size: Dual Focus 0.1/0.3mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
High-speed anode drive: 2800/1000rpm
Target angle: 10°/16°
Anode Heat Storage: 210kJ (300kHU)
Anode Cooling: Air cooling
Filtration: Mo(0.03mm), Al(0.5mm)
3) VARIAN B115 tube from America
Focal Spot Size: Dual Focus 0.1/0.3mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
High-speed anode drive: 2800/1000rpm
Target angle: 10°/16°
Anode Heat Storage: 210kJ (300kHU)
Anode Cooling: Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
- Radiographic Stand
C-ARM: Vertical Movement: 590mm
Center of electric rotating C-arm, automatic return function by one key
Automatically released after the exposure pressure settings display
Compression flexible stepless speed.
Max. pressure: 200N
Max. travel: 150mm
Rotations Deg:+90°~-90°
SID: 650mm
- Cassette Image Receptor
18*24cm (24cm*30cm optional)
Bucky Device: 18*24cm Bucky drive mechanism,(24cm*30cm optional)
Grid Ratio: 5:1, 30 Line/cm
- Line Voltage
220Vac@25A, Single phase
- Weight and Size:
240kg(Gross weight: 340kg)
L*W×H: 940mm*560mm*2000mm
Upgrading:
Above introduction for ARI-9800D is an analog mammography, actually, it can be upgraded into a DR system. Here is the main parameters for digital mammography.
Main Parameters for Full Digital Mammography System |
Name |
Parameters |
Specialized Digital Flat Panel Detector for Mammography |
Detector, Power Box, Date Line, Capture Card, etc |
Effective Coverage of Detector |
23*15cm, 29*23cm |
Pixel Matrix |
3072*1944, 3888*3072 |
Limit of Spatial Resolution |
6.0Lp/mm |
DQE Value |
70% |
Dynamic Range |
14bit digital output |
Pixel Size |
75um |
High Voltage Synchronizer |
BNC |
Output |
Camera Link or Ethernet |
Working Condition |
10-40℃ |
Storage Environment |
-10-50℃ |
Bucky |
Housing and Movement Device |
Size |
370*275*125cm |
Stepless Speed Regulating Range |
0-6cm/s |
Movement Range |
0.5-2cm |
Grid |
Size |
24*30cm |
Grid Ratio |
3.5:1 |
Focal Distance |
65cm |
Software |
Workstation |
Standard Detector Image Acquisition Workstation |
CPU≥Intel Duo Core 2.60GHz |
Hardware≥250G |
Memory≥2G |
Display Card≥512MB |
19’’ High Brightness High Contrast LCD, 1280*1024 Pixel Resolution |
Network Interface Worklist |
DICOM3.0 Transmission |