Patient Monitor

Availability: In Stock

Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable

SKU: intelligent-cotton-wallet-84284228 Categories: , Tag:

Description

ARI-800B+ Patient Monitor

15 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR

1.13 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;

  1. Efficient resistance to interference of defibrillator and electrosurgical cautery;
  2. SPO2 can testing for 0.1% Weak;
  3. RA-LL impedance Respiration;
  4. Trend Coexist Display;
  5. Oxy-CRG Dynamic View Display;
  6. Bed to Bed view Display;
  7. Networking capacity and nurse calling system;
  8. Options of printing, IBP, VGA and EtCO2;
  9. UP to 4 hours working capacity of built-in rechargeable battery;

11.15″ high resolution color TFT LCD display;

  1. Large volume of tabular and graphic trends information storage and easy to recall;
  2. Anti-ESU, anti- defibrillator;
  3. Capture dynamic waveforms.

Technical specification: ECG

Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

HR and Alarm

Range

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great

Resolution: 1 bpm

Sensitivity: > 200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR

Monitor: > 105 dB

Operation: > 105 dB

Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: < 10uA

Baseline Recovery: < 3 S after Defi.

ECG Signal Range: ±8 m V (Vp-p)

Bandwidth

Surgery: 1 ~ 15 Hz

Monitor: 0.5 ~ 35 Hz

Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

RESPIRATION

Method: Impedance between R-F (RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range: 0.3~5.0Ω

Base line Impedance Range: 0 – 2.5 KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

Adult: 0 ~ 120 rpm

Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy: ±2 rpm

Apean Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range

Adult Mode

SYS: 40 ~ 270 mmHg

DIA: 10 ~ 215 mmHg

MEAN: 20 ~ 235 mmHg

Pediatric Mode

SYS: 40 ~ 200 mmHg

DIA: 10 ~ 150 mmHg

MEAN: 20 ~ 165 mmHg

Neonatal Mode

SYS: 40 ~ 135 mmHg

DIA: 10 ~ 100 mmHg

MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

Adult Mode: 297±3 mmHg

Pediatric Mode: 240±3 mmHg

Neonatal Mode: 147±3 mmHg

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %

0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy: ±2bpm

TEMPERATURE

Channel: 2

Measuring and Alarm Range: 0 ~ 50 °C

Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec.

Average Time Constant: <10 Sec.

IBP

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

ART: 0 ~ 300 mmHg

PA: -6 ~ 120 mmHg

CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

P1/P2: -10 ~ 300 mmHg

Press Sensor

Sensitivity: 5uV/V/mmHg

Impedance: 300-3000Ω

Resolution: 1 mmHg

Accuracy: ±2% or ±1mmHg, which great

Actualization interval: about 1 Sec

Standard Packing List:

5-lead ECG cable (including RESP)

Adult finger SpO2 sensor

Adult NIBP cuff

NIBP extension tube

TEMP sensor

AC power adaptor

ECG electrodes

Operation instruction

Selectable Accessory:

Child finger SPO2 sensor

Child NIBP cuff

Neonate NIBP cuff

Reviews

There are no reviews yet.

Be the first to review “Patient Monitor”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPatient Monitor removeBlood Bank Refrigerator removeLed Operating Lamp YD02–5+5 removeTrolleys and Mayo Table removeExamination Lamp YD O1A (LED) remove
NamePatient Monitor removeBlood Bank Refrigerator removeLed Operating Lamp YD02–5+5 removeTrolleys and Mayo Table removeExamination Lamp YD O1A (LED) remove
Image
SKUintelligent-cotton-wallet-84284228intelligent-rubber-computer-39225733awesome-leather-coat-50022656incredible-wooden-knife-55493482
Rating
Price4,000,000.0090,000.00
Stock

38 in stock (can be backordered)

Availability38 in stock (can be backordered)
Add to cart

Read more

Read more

Add to cart

Read more

Add to cart

DescriptionMulti-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotableThe Blood Bank Refrigerator is a specialized refrigerating equipment for blood (whole blood) storage application.Excellent cold light: adopting LED as light source, without temperature rising.Stainless Steel Mayo Table Operation Instrument Trolley
advanced lighting equipment at home and abroad.
Content

ARI-800B+ Patient Monitor

15 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR 1.13 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
  1. Efficient resistance to interference of defibrillator and electrosurgical cautery;
  2. SPO2 can testing for 0.1% Weak;
  3. RA-LL impedance Respiration;
  4. Trend Coexist Display;
  5. Oxy-CRG Dynamic View Display;
  6. Bed to Bed view Display;
  7. Networking capacity and nurse calling system;
  8. Options of printing, IBP, VGA and EtCO2;
  9. UP to 4 hours working capacity of built-in rechargeable battery;
11.15" high resolution color TFT LCD display;
  1. Large volume of tabular and graphic trends information storage and easy to recall;
  2. Anti-ESU, anti- defibrillator;
  3. Capture dynamic waveforms.
Technical specification: ECG Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) Lead selection: I, II, III, avR, avL, avF, V, Waveform: 2ch Lead mode: 3 Leads (R, L, F or RA, LA, LL) Lead selection: I, II, III, Waveform: 1ch Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto HR and Alarm Range Adult: 15 ~ 300 bpm Neo/Ped: 15 ~ 350 bpm Accuracy: ± 1% or ± 1bpm, which great Resolution: 1 bpm Sensitivity: > 200 (uV P-P) Differential Input Impedance: > 5 MΩ CMRR Monitor: > 105 dB Operation: > 105 dB Diagnosis: > 85 dB Electrode offset potential: ±300mV Leakage Current: < 10uA Baseline Recovery: < 3 S after Defi. ECG Signal Range: ±8 m V (Vp-p) Bandwidth Surgery: 1 ~ 15 Hz Monitor: 0.5 ~ 35 Hz Diagnostic: 0.05 ~ 100 Hz Calibration Signal: 1 (mV p-p), Accuracy: ±5% ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm: Available Review: Available RESPIRATION Method: Impedance between R-F (RA-LL) Differential Input Impedance: >2.5 MΩ Measuring Impedance Range: 0.3~5.0Ω Base line Impedance Range: 0 – 2.5 KΩ Bandwidth: 0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range Adult: 0 ~ 120 rpm Neo/Ped: 0 ~ 150 rpm Resolution: 1 rpm Accuracy: ±2 rpm Apean Alarm: 10 ~ 40 S NIBP Method: Oscillometric Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode: 5 Min Pulse Rate Range: 40 ~ 240 bpm Alarm Type: SYS, DIA, MEAN Measuring and alarm range Adult Mode SYS: 40 ~ 270 mmHg DIA: 10 ~ 215 mmHg MEAN: 20 ~ 235 mmHg Pediatric Mode SYS: 40 ~ 200 mmHg DIA: 10 ~ 150 mmHg MEAN: 20 ~ 165 mmHg Neonatal Mode SYS: 40 ~ 135 mmHg DIA: 10 ~ 100 mmHg MEAN: 20 ~ 110 mmHg Resolution Pressure: 1mmHg Accuracy Pressure Maximum Mean error: ±5mmHg Maximum Standard deviation: ±8mmHg Overpressure Protection Adult Mode: 297±3 mmHg Pediatric Mode: 240±3 mmHg Neonatal Mode: 147±3 mmHg SpO2 Measuring Range: 0 ~ 100 % Alarm Range: 0 ~ 100 % Resolution: 1 % Accuracy: 70% ~ 100% ±2 % 0% ~ 69% unspecified Actualization interval: about 1 Sec. Alarm Delay: 10 Sec. Pulse Rate Measuring and Alarm Range: 20~300bpm Resolution: 1bpm Accuracy: ±2bpm TEMPERATURE Channel: 2 Measuring and Alarm Range: 0 ~ 50 °C Resolution: 0.1°C Accuracy: ±0.1°C Actualization interval: about 1 Sec. Average Time Constant: <10 Sec. IBP Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and alarm range ART: 0 ~ 300 mmHg PA: -6 ~ 120 mmHg CVP/RAP/LAP/ICP: -10 ~ 40 mmHg P1/P2: -10 ~ 300 mmHg Press Sensor Sensitivity: 5uV/V/mmHg Impedance: 300-3000Ω Resolution: 1 mmHg Accuracy: ±2% or ±1mmHg, which great Actualization interval: about 1 Sec Standard Packing List: 5-lead ECG cable (including RESP) Adult finger SpO2 sensor Adult NIBP cuff NIBP extension tube TEMP sensor AC power adaptor ECG electrodes Operation instruction Selectable Accessory: Child finger SPO2 sensor Child NIBP cuff Neonate NIBP cuff

Stainless Steel Blood Bank Refrigerator (+4°C)

  The Blood Bank Refrigerator is a specialized refrigerating equipment for blood (whole blood) storage application, which has been used in medical industries as well as cold storage of pharmaceuticals, biological products, vaccine, and so forth.it is suitable for hospitals, blood banks and sanitation and ant epidemic stations.

Control System:

-Microprocessor-based temperature controller. Temperature range 4±1°C, with temperature printer standard. -Large screen LCD display of temperature, display accuracy of +/- 0.1°C. -Automatic temperature control, Defrost automatic -Audible and visual alarm: High or low temperature alarm, Door ajar alarm, system failure alarm, power failure alarm, low battery alarm. -Power supply: 220V 50Hz 1 phase, can be changed as 220V 60HZ or 110V 50/60HZ  

Structure Design:

-Upright type, Exterior made from painted steel plate, Inside is stainless steel. -Four units Caster are mounted under the bottom -Three-layer glass door with heater around to prevent ice leak, and lockable. -Interior fluorescent light -Inner is shelves (wire plastics). 3units for ABR-88L, 4units for ABR-268L, 5units for ABR-358L, 6units for ABR-588L. -Temperature printer is standard, Optional chart recorder, blood storage basket.  

Refrigeration System:

-Forced air circulation system -International Famous compressor and Germany EBM fan motors -The high-effective air-cooled condenser and the fin-type evaporator -Refrigerant as R134a, CFC free -Certificate: CE mark, ISO9001, ISO14001, ISO13485

Specifications:

 
Model Capacity (L) External size (D*W*H)mm Interior size (D*W*H)mm Blood capacity Weight (KG)
ABR-88L 88 500*450*1515 402*343*663 450ml/bag*40-50/bags 90/100
ABR-268L 268 700*628*1662 512*518*973 450ml/bag*100-140/bags 160/170
ABR-358L 358 700*628*1962 512*515*1270 450ml/bag*180-220/bags 200/210
ABR-588L 588 800*760*1977 550*560*1260 450ml/bag*250-300/bags 230/240

Features

-Excellent cold light: adopting LED as light source, without temperature rising. -Excellent daylight quality and CRI meet the illumination needs of the doctors. -Long service life: LED life is up to 30,000 hours. -Energy saving and environment-friendly. Technical Specifications

PARAMETER SPECIFICATION

Illuminance ≥100,000Lux Color Temperature 4800±300K Illuminance Depth ≥500mm Size of Light Field 160~220mm Rated Power of Bulb 3.2V/1W (80pc LED bulb) Power Supply Voltage 220V/50Hz LED Bulb Life ≥30,000 hr

Quick Details

Type: Hospital Furniture Specific Use: Hospital Table General Use: Commercial Furniture Material: Metal Metal Type: Stainless Steel Folded: No Size: 600*400*750-1050mm Brand Name: WCM Model Number: WCM-F-F124 Product Name: Stainless Steel Mayo Table Operation Instrument Trolley Color: customizable Feature: Adjustable Accessories: wheels  

Technical Specifications

Illuminance 30,000Lux 0.5m / 10,000Lux 1m Color Temperature 4800±200K Size of Light Field 100mm Adjust Adjust light Power Supply Voltage 220V/50Hz Rated Power of Bulb 3.3V/3W Crutch Adjust up/down Bulb LED bulb

Product Features

-YD01A (LED) examination lamp is extensively applied in industry, medical treatment, jewelry, photograph scientific research etc. -It is currently more advanced lighting equipment at home and abroad.
WeightN/AN/AN/AN/A130 kg
DimensionsN/AN/AN/AN/A43 × 51 × 78 cm
Additional information
size

Cycling, Football, Running, Swimming

Weight 130 kg
Dimensions 43 × 51 × 78 cm