Laparoscopy Equipment

Availability: In Stock

Suggest to be used for laparoscope, hysteroscope etc.

SKU: aerodynamic-paper-pants-68080839 Categories: ,

Description

Main Features

1. Adopt 1/2.8inch SONY CMOS HD camera.

2. With 2,100,000 total pixels, 1920*1080p image size and TV line 1080lines

3. Professional video out: CVBS, S-VIDEO, DVI, HDMI

4. 5inch LCD screen

5. Suggest to be used for laparoscope, hysteroscope etc.

 

Image show

 

Complete set endoscopy laparoscopy equipments machine

 

Reviews

There are no reviews yet.

Be the first to review “Laparoscopy Equipment”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsLaparoscopy Equipment removeObstetric kits removePortable Digital Slit Lamp removeInfant Incubator removeMammography System removePeritoneal dialysis remove
NameLaparoscopy Equipment removeObstetric kits removePortable Digital Slit Lamp removeInfant Incubator removeMammography System removePeritoneal dialysis remove
Image
SKUaerodynamic-paper-pants-68080839awesome-copper-bench-14388408enormous-copper-plate-06844431small-linen-bag-63969771Mammography Systemincredible-bronze-car-73915645
Rating
Price
Stock

Available on backorder

10 in stock

AvailabilityAvailable on backorder10 in stock
Add to cart

Read more

Read more

Read more

Read more

Select options

Read more

DescriptionSuggest to be used for laparoscope, hysteroscope etc.Obstetric kits are used for emergency deliveries.AME-5S3 Portable Digital Slit Lamp Microscope is produced with high illumination white LED, and can be used about 5 to 6 hours continuously after fully recharged.Set temperature, air temperature, baby skin temperature, timer and heating power are displayed separately by LEDNew appearance, There are three large size full color LCD screen on the machine, and one 8 inch LCD touch screen on the console.Peritoneal dialysis involves surgery to implant a peritoneal dialysis (PD) catheter into your abdomen.
ContentMain Features 1. Adopt 1/2.8inch SONY CMOS HD camera. 2. With 2,100,000 total pixels, 1920*1080p image size and TV line 1080lines 3. Professional video out: CVBS, S-VIDEO, DVI, HDMI 4. 5inch LCD screen 5. Suggest to be used for laparoscope, hysteroscope etc.   Image show   Complete set endoscopy laparoscopy equipments machine  

Obstetric kits

Obstetric kits are used for emergency deliveries. They contain a variety of items like: Under pad 23” x 36” Sterile Obstetric Pad Sterile Bulb Aspirator 2 oz Umbilical Cord Clamps – 2 No. 2 Pairs of Sterile Latex Free Examination Gloves – Large 1No. Placenta Scalpel #22 1No. Receiving Blanket 3No Disposable Towels 4No. Sterile Gauze Sponges 1No. Disposable Apron 2No. Twist Ties Apgar Scoring Chart Basic Drugs – Paracetamol Tablets, Ibuprofen Tablets and Cotrimoxazole Tablets, Methylated Spirit, Gentian Violet

Portable Digital Slit Lamp

AME-5S3 Portable Digital Slit Lamp Microscope is produced with high illumination white LED, and can be used about 5 to 6 hours continuously after fully recharged. The net weight is 750 g only, so that very convenient to be carried. And very proud that it is the very initial and most advanced portable model in China. With Nikon Camera & Camera adaptor & Background illumination & Fixation Lamp Microscope type: Binocular crossed stereo microscope

Total Magnification:

10 x Eyepiece 16 x Eyepiece
1 x Objective 10 16
Diopter compensation:-7D~+7D Working distance: 80mm Slit width: 0~10mm continuously adjustable Slit height: 1mm, 3mm, 5mm, 10mm Diameter of light spot: 1mm, 3mm, 5mm, 10mm Filter: heating absorption, 50%ND, Red-free, blue Illumination Rotate Angle: horizontal ±30 degree Illumination: White LED Input Voltage: AC 100~240V, 60~50HZ Input Power: 18VA  

Infant Incubator

Features: -Microprocessor based servo-controlled temperature system -Control modes: Air mode and baby skin mode -Humidity is adjustable continuously -Set temperature, air temperature, baby skin temperature, timer and heating power are displayed separately by LED -Self - testing function, various failure alarms by audible and visual ->37℃ temperature set function -Triple protection for over temperature with separate cut off device, more safety system -The inclination of infant bed is adjustable -Single wall hood, 4 operating windows and 2 iris ports -Independent locking device for front door -RS232 connector -Oxygen inlet -Cabinet with four drawers

Specifications:

-Power supply AC110/220V 60/50Hz -Power input 650VA Operating condition -Environment temperature 20℃~30℃ -Environment relative humidity 30%~75% -Environment air velocity of flow <0.3m/s -Air temperature control range 25℃~37℃ 37.1℃~38℃ -Skin temperature control range 32℃~37℃ 37.1℃~38℃ -Skin temperature sensor accuracy ±0.3℃ -Temperature fluctuation ±0.5℃ -Uniformity of mattress temperature ≤0.8℃ -Warm-up time(from25℃) <30min -Internal noise level <50dB(A) -Infant bed tilt angle ±10° -Mattress size 65cm(L)*37cm(W) -Trough capacity 1200mL -Air filter 0.5μm

Optional Functions:

-Humidity display system -Humidity control system -X ray cassette Tray; -Baby weight system -Electric height adjustable -LED phototherapy unit AL-3D, AL-10D -Air and oxygen blender -Double wall hood -Air & Oxygen Blender

Mammography System

Features:

New appearance, There are three large size full color LCD screen on the machine, and one 8 inch LCD touch screen on the console.

Main Parameters:

Three different X-ray tubes to choose:

-- Hangzhou LR01 tube from China

-- IAE C339V tube from Italy

-- VARIAN B115 tube from America

  1. X-ray Generator

Complete solid-state high-frequency high-voltage generator.

Generator Type: High Frequency Inverter 80kHz

Input Power: Single phase 220VAC, 50/60Hz

Radiographic Ratings: Large Focal Point 20-35kV/10-510mAs

Small Focal Point 20-35kV/10-100mAs

Power Rating: 6.2kW

  1. X-ray Tube

1) Hangzhou LR01 tube from China

Focal Spot Size: Dual Focus 0.2 / 0.4mm

Target Material:Molybdenum (Mo)

Port Material:Beryllium (Be)

High-speed anode drive: 2800/1000rpm

Target angle: 12°/12°

Anode Heat Storage: 100KJ (150kHU)

Anode Cooling:Air cooling

Filtration: Mo(0.03mm),Al(0.5mm)

2) IAE C339V tube from Italy

Focal Spot Size: Dual Focus 0.1/0.3mm

Target Material: Molybdenum (Mo)

Port Material: Beryllium (Be)

High-speed anode drive: 2800/1000rpm

Target angle: 10°/16°

Anode Heat Storage: 210kJ (300kHU)

Anode Cooling: Air cooling

Filtration: Mo(0.03mm), Al(0.5mm)

3) VARIAN B115 tube from America

Focal Spot Size: Dual Focus 0.1/0.3mm

Target Material: Molybdenum (Mo)

Port Material: Beryllium (Be)

High-speed anode drive: 2800/1000rpm

Target angle: 10°/16°

Anode Heat Storage: 210kJ (300kHU)

Anode Cooling: Air cooling

Filtration: Mo(0.03mm),Al(0.5mm)

  1. Radiographic Stand

C-ARM: Vertical Movement: 590mm

Center of electric rotating C-arm, automatic return function by one key

Automatically released after the exposure pressure settings display

Compression flexible stepless speed.

Max. pressure: 200N

Max. travel: 150mm

Rotations Deg:+90°~-90°

SID: 650mm

  1. Cassette Image Receptor

18*24cm (24cm*30cm optional)

Bucky Device: 18*24cm Bucky drive mechanism,(24cm*30cm optional)

Grid Ratio: 5:1, 30 Line/cm

  1. Line Voltage

220Vac@25A, Single phase

  1. Weight and Size:

240kg(Gross weight: 340kg)

L*W×H: 940mm*560mm*2000mm

Upgrading:

Above introduction for ARI-9800D is an analog mammography, actually, it can be upgraded into a DR system. Here is the main parameters for digital mammography.

Main Parameters for Full Digital Mammography System
Name Parameters
Specialized Digital Flat Panel Detector for Mammography Detector, Power Box, Date Line, Capture Card, etc
Effective Coverage of Detector 23*15cm, 29*23cm
Pixel Matrix 3072*1944, 3888*3072
Limit of Spatial Resolution 6.0Lp/mm
DQE Value 70%
Dynamic Range 14bit digital output
Pixel Size 75um
High Voltage Synchronizer BNC
Output Camera Link or Ethernet
Working Condition 10-40℃
Storage Environment -10-50℃
Bucky Housing and Movement Device
Size 370*275*125cm
Stepless Speed Regulating Range 0-6cm/s
Movement Range 0.5-2cm
Grid
Size 24*30cm
Grid Ratio 3.5:1
Focal Distance 65cm
Software
Workstation Standard Detector Image Acquisition Workstation
CPU≥Intel Duo Core 2.60GHz
Hardware≥250G
Memory≥2G
Display Card≥512MB
19’’ High Brightness High Contrast LCD, 1280*1024 Pixel Resolution
Network Interface Worklist
DICOM3.0 Transmission
100/1000 Gigabit Ethernet
Peritoneal dialysis involves surgery to implant a peritoneal dialysis (PD) catheter into your abdomen. The catheter helps filter your blood through the peritoneum, a membrane in your abdomen. During treatment, a special fluid called dialysate flows into the peritoneum. The dialysate absorbs waste. Once the dialysate draws waste out of the bloodstream, it’s drained from your abdomen. This process takes a few hours and needs to be repeated four to six times per day. However, the exchange of fluids can be performed while you’re sleeping or awake. There are numerous different types of peritoneal dialysis. The main ones are:
  • Continuous ambulatory peritoneal dialysis (CAPD). In CAPD, your abdomen is filled and drained multiple times each day. This method doesn’t require a machine and must be performed while awake.
  • Continuous cycling peritoneal dialysis (CCPD). CCPD uses a machine to cycle the fluid in and out of your abdomen. It’s usually done at night while you sleep.
  • Intermittent peritoneal dialysis (IPD). This treatment is usually performed in the hospital, though it may be performed at home. It uses the same machine as CCPD, but the process takes longer.
WeightN/A52 kgN/A136 kg56 kg129 kg
DimensionsN/A19 × 47 × 134 cmN/A105 × 126 × 35 cm114 × 22 × 158 cm185 × 119 × 173 cm
Additional information
Weight 52 kg
Dimensions 19 × 47 × 134 cm
Weight 136 kg
Dimensions 105 × 126 × 35 cm
Weight 56 kg
Dimensions 114 × 22 × 158 cm
Weight 129 kg
Dimensions 185 × 119 × 173 cm