Description | Suggest to be used for laparoscope, hysteroscope etc. | New appearance, There are three large size full color LCD screen on the machine, and one 8 inch LCD touch screen on the console. | The modern lifestyle has made various health risks such as hypertension, heart disease, and other common cardiovascular conditions increasingly common. Picking the right sphygmomanometer is a smart choice that we should all consider daily, for the good of our healthy bodies. | Set temperature, air temperature, baby skin temperature, timer and heating power are displayed separately by LED | Peritoneal dialysis involves surgery to implant a peritoneal dialysis (PD) catheter into your abdomen. | Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. |
Content | Main Features
1. Adopt 1/2.8inch SONY CMOS HD camera.
2. With 2,100,000 total pixels, 1920*1080p image size and TV line 1080lines
3. Professional video out: CVBS, S-VIDEO, DVI, HDMI
4. 5inch LCD screen
5. Suggest to be used for laparoscope, hysteroscope etc.
Image show
| Mammography System
Features:
New appearance, There are three large size full color LCD screen on the machine, and one 8 inch LCD touch screen on the console.
Main Parameters:
Three different X-ray tubes to choose:
-- Hangzhou LR01 tube from China
-- IAE C339V tube from Italy
-- VARIAN B115 tube from America
- X-ray Generator
Complete solid-state high-frequency high-voltage generator.
Generator Type: High Frequency Inverter 80kHz
Input Power: Single phase 220VAC, 50/60Hz
Radiographic Ratings: Large Focal Point 20-35kV/10-510mAs
Small Focal Point 20-35kV/10-100mAs
Power Rating: 6.2kW
- X-ray Tube
1) Hangzhou LR01 tube from China
Focal Spot Size: Dual Focus 0.2 / 0.4mm
Target Material:Molybdenum (Mo)
Port Material:Beryllium (Be)
High-speed anode drive: 2800/1000rpm
Target angle: 12°/12°
Anode Heat Storage: 100KJ (150kHU)
Anode Cooling:Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
2) IAE C339V tube from Italy
Focal Spot Size: Dual Focus 0.1/0.3mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
High-speed anode drive: 2800/1000rpm
Target angle: 10°/16°
Anode Heat Storage: 210kJ (300kHU)
Anode Cooling: Air cooling
Filtration: Mo(0.03mm), Al(0.5mm)
3) VARIAN B115 tube from America
Focal Spot Size: Dual Focus 0.1/0.3mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
High-speed anode drive: 2800/1000rpm
Target angle: 10°/16°
Anode Heat Storage: 210kJ (300kHU)
Anode Cooling: Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
- Radiographic Stand
C-ARM: Vertical Movement: 590mm
Center of electric rotating C-arm, automatic return function by one key
Automatically released after the exposure pressure settings display
Compression flexible stepless speed.
Max. pressure: 200N
Max. travel: 150mm
Rotations Deg:+90°~-90°
SID: 650mm
- Cassette Image Receptor
18*24cm (24cm*30cm optional)
Bucky Device: 18*24cm Bucky drive mechanism,(24cm*30cm optional)
Grid Ratio: 5:1, 30 Line/cm
- Line Voltage
220Vac@25A, Single phase
- Weight and Size:
240kg(Gross weight: 340kg)
L*W×H: 940mm*560mm*2000mm
Upgrading:
Above introduction for ARI-9800D is an analog mammography, actually, it can be upgraded into a DR system. Here is the main parameters for digital mammography.
Main Parameters for Full Digital Mammography System |
Name |
Parameters |
Specialized Digital Flat Panel Detector for Mammography |
Detector, Power Box, Date Line, Capture Card, etc |
Effective Coverage of Detector |
23*15cm, 29*23cm |
Pixel Matrix |
3072*1944, 3888*3072 |
Limit of Spatial Resolution |
6.0Lp/mm |
DQE Value |
70% |
Dynamic Range |
14bit digital output |
Pixel Size |
75um |
High Voltage Synchronizer |
BNC |
Output |
Camera Link or Ethernet |
Working Condition |
10-40℃ |
Storage Environment |
-10-50℃ |
Bucky |
Housing and Movement Device |
Size |
370*275*125cm |
Stepless Speed Regulating Range |
0-6cm/s |
Movement Range |
0.5-2cm |
Grid |
Size |
24*30cm |
Grid Ratio |
3.5:1 |
Focal Distance |
65cm |
Software |
Workstation |
Standard Detector Image Acquisition Workstation |
CPU≥Intel Duo Core 2.60GHz |
Hardware≥250G |
Memory≥2G |
Display Card≥512MB |
19’’ High Brightness High Contrast LCD, 1280*1024 Pixel Resolution |
Network Interface Worklist |
DICOM3.0 Transmission |
100/1000 Gigabit Ethernet |
| Aneroid Sphygmomanometer
Say the words “aneroid sphygmomanometer” to most people in the country, and they will look at you confused. Say them to any person in the medical community, and they will immediately know you are talking about a blood pressure monitoring device. Aneroid sphygmomanometers are comprised of an inflatable cuff that collapses then releases the artery under the cuff in a precisely controlled manner.
Inside of the device, a mercury or mechanical manometer is used to measure the pressure in conjunction with a device to measure the pressure where blood flow is just starting and at what pressure it is unimpeded. Manual aneroid sphygmomanometers are used with a stethoscope to hear these points.
Product Features
- Needs and Price: The right sphygmomanometer is determined by the needs and requirements of its user.
- Accuracy: As with any medical instrument, the accuracy of measurements is of utmost importance.
- Quality, Design, and Cuff Size: Sphygmomanometers vary according to their quality of material and design, all of which affect the overall performance of the device.
| Infant Incubator
Features:
-Microprocessor based servo-controlled temperature system
-Control modes: Air mode and baby skin mode
-Humidity is adjustable continuously
-Set temperature, air temperature, baby skin temperature, timer and heating power are displayed separately by LED
-Self - testing function, various failure alarms by audible and visual
->37℃ temperature set function
-Triple protection for over temperature with separate cut off device, more safety system
-The inclination of infant bed is adjustable
-Single wall hood, 4 operating windows and 2 iris ports
-Independent locking device for front door
-RS232 connector
-Oxygen inlet
-Cabinet with four drawers
Specifications:
-Power supply AC110/220V 60/50Hz
-Power input 650VA
Operating condition
-Environment temperature 20℃~30℃
-Environment relative humidity 30%~75%
-Environment air velocity of flow <0.3m/s
-Air temperature control range 25℃~37℃ 37.1℃~38℃
-Skin temperature control range 32℃~37℃ 37.1℃~38℃
-Skin temperature sensor accuracy ±0.3℃
-Temperature fluctuation ±0.5℃
-Uniformity of mattress temperature ≤0.8℃
-Warm-up time(from25℃) <30min
-Internal noise level <50dB(A)
-Infant bed tilt angle ±10°
-Mattress size 65cm(L)*37cm(W)
-Trough capacity 1200mL
-Air filter 0.5μm
Optional Functions:
-Humidity display system
-Humidity control system
-X ray cassette Tray;
-Baby weight system
-Electric height adjustable
-LED phototherapy unit AL-3D, AL-10D
-Air and oxygen blender
-Double wall hood
-Air & Oxygen Blender | Peritoneal dialysis involves surgery to implant a peritoneal dialysis (PD) catheter into your abdomen. The catheter helps filter your blood through the peritoneum, a membrane in your abdomen. During treatment, a special fluid called dialysate flows into the peritoneum. The dialysate absorbs waste. Once the dialysate draws waste out of the bloodstream, it’s drained from your abdomen.
This process takes a few hours and needs to be repeated four to six times per day. However, the exchange of fluids can be performed while you’re sleeping or awake.
There are numerous different types of peritoneal dialysis. The main ones are:
- Continuous ambulatory peritoneal dialysis (CAPD). In CAPD, your abdomen is filled and drained multiple times each day. This method doesn’t require a machine and must be performed while awake.
- Continuous cycling peritoneal dialysis (CCPD). CCPD uses a machine to cycle the fluid in and out of your abdomen. It’s usually done at night while you sleep.
- Intermittent peritoneal dialysis (IPD). This treatment is usually performed in the hospital, though it may be performed at home. It uses the same machine as CCPD, but the process takes longer.
| Standard mattress for a hospital bed in polyurethane foam, with removable PVC cover for easy cleaning and replacing. Foam density is one of the factors determining the quality and durability. Low grades are from 18 to 22kg/m³; medium grades from 22 to 27 kg/m³; high grades above 27kg/m³. (1lb/sqft = 15kg/m³). A minimum quality for hospital bed mattress should be 27kg/m³.
The factor determining the firmness is the Indentation Load Deflexion. This factor may vary from 5 to 100kg. For bed mattresses an average of 15 to 16kg is recommended.
The cover must be PVC-coated canvas. A plain PVC sheet is not strong enough. A light colour material is necessary to encourage cleaning. This cover must resist washing with chlorine.
Higher quality mattresses are made with latex foam and/or springs.
Special types of medical mattresses are not described here.
Specifications
Product Features
01. Type of foam
Polyurethane closed cell foam, 35kg/m³, thickness: 10cm,
Indentation Load Deflection 16kg min.
02. Cover
- made of a light-colour PVC-coated polyester canvas of 250g/m² minimum;
- tear strength 10da N min. under ISO 9073-4.
- equipped with a strong plastic zip of the length of the mattress.
- material to resist washing and disinfection with chlorine 0.5%
- Sown with impervious seams
When a Mattress cover is purchased alone, it is imperative that the requester indicates the exact mattress size (Length x width x height) for proper mattress fitting so to avoid the wrinkling of the cover which could create bedsores for the patient
02. Packaging
Individually wrapped in plastic foil, not compressed. In compressed bales for air transport in large quantities, the compression must be flat only - not rolled, not folded. |
Reviews